{"requirement_id":"JDDG25-14.8.3.3-R05","source":{"document":"Japan District Design Guide","version":"9.0","publication_date":"2025-04","chapter":"14","section":"14.8.3.3","title":"DESIGN ANALYSIS","page_printed":242,"page_pdf":272,"fact":"Seismic-protection calculations may be performed by a registered U.S. engineer or a Japanese 1st Class Qualified Architect.","modality":"may","strength":"permission"},"localization_ja":{"language":"ja","title_ja":"設計解析書","title_status":"controlled_editorial","fact_ja":null,"fact_translation_status":"pending","modality_rendering_ja":"～してよい","strength_label_ja":"許可","translation_priority":"medium","translation_notes":[],"title_translation_provenance":"editorial_controlled","fact_translation_provenance":"not_translated","publication_eligible":false},"references":[],"meaning":{"engineering_basis":null,"engineering_basis_source":null,"engineering_interpretation":null,"interpretation_confidence":null},"risk":{"failure_modes":[],"failure_mode_source":"not_stated","failure_domains":[]},"quality":{"source_status":"normal","data_quality_flag":"normal"},"applicability":{"applicability_class":"general","evaluation_mode":"default_applicable","evaluation_scope":"project","input_semantics":"none","source_condition_text":null,"trigger":null,"approval_gate":null,"exception_condition":null,"condition_provenance":"none","normalization_provenance":"none"},"lifecycle":{"primary_phase":"design/intermediate","primary_phase_label":"Intermediate Design","applicable_phases":["design","design/intermediate"],"phase_links":[{"phase":"design","provenance":"jddg_cross_section_explicit","basis":"Linked to separate JDDG Section 14.8 design evidence/submittal requirements.","phase_label":"Design"},{"phase":"design/intermediate","provenance":"source_explicit","basis":"Section 14.8.3 is Intermediate Design.","phase_label":"Intermediate Design"}]},"responsibility":{"primary_workflow_owner":"ACT-DESIGNER-AE","primary_workflow_owner_name":"Designer / A-E","actor_assignment_status":"source_actor_present","actors":[{"actor_id":"ACT-REGISTERED-US-ENGINEER","actor_name":"Registered U.S. Engineer","actor_class":"qualified_professional","source_named":true,"relation_type":"qualified_calculation_actor","provenance":"source_explicit","lifecycle_phase":"design","lifecycle_phase_label":"Design","basis":"Source explicitly permits a registered U.S. engineer to perform the calculation."},{"actor_id":"ACT-JP-FIRST-CLASS-ARCHITECT","actor_name":"Japanese 1st Class Qualified Architect","actor_class":"qualified_professional","source_named":true,"relation_type":"qualified_calculation_actor","provenance":"source_explicit","lifecycle_phase":"design","lifecycle_phase_label":"Design","basis":"Source explicitly permits a Japanese 1st Class Qualified Architect to perform the calculation."},{"actor_id":"ACT-DESIGNER-AE","actor_name":"Designer / A-E","actor_class":"project_delivery","source_named":true,"relation_type":"workflow_owner","provenance":"editorial_derived","lifecycle_phase":"design","lifecycle_phase_label":"Design","basis":"Workflow owner assigned from lifecycle phase for checklist routing; not a contractual responsibility statement."},{"actor_id":"ACT-DESIGNER-AE","actor_name":"Designer / A-E","actor_class":"project_delivery","source_named":true,"relation_type":"workflow_owner","provenance":"editorial_derived","lifecycle_phase":"design/intermediate","lifecycle_phase_label":"Intermediate Design","basis":"Workflow owner assigned from lifecycle phase for checklist routing; not a contractual responsibility statement."}]},"verification":{"method":"engineering_analysis_review","stage":["design"],"acceptance_criteria":null,"evidence_required":["engineering_calculation_or_analysis"],"verification_provenance":"source_implied","evidence_provenance":"source_implied","audit_status":"source_implied_verification","audit_confidence":"high","acceptance_provenance":"not_stated_in_jddg","evidence_type_ids":["EV-SEISMIC-CALC","EV-FINAL-CALCULATIONS"],"supporting_source_requirements":["JDDG25-14.8.3.3-R05","JDDG25-14.8.4.3-R02"],"source_support_scope":"design_submittal_or_analysis"},"resolved_evidence":[{"evidence_type_id":"EV-SEISMIC-CALC","name":"Seismic-protection calculations","source_requirement_ids":["JDDG25-14.8.3.3-R05"],"stage":["intermediate_design"],"source_scope":"JDDG identifies qualified professionals who may perform seismic-protection calculations."},{"evidence_type_id":"EV-FINAL-CALCULATIONS","name":"Final engineering calculations","source_requirement_ids":["JDDG25-14.8.4.3-R02"],"stage":["final_design"],"source_scope":"All final calculations are included in the Final Design Analysis."}],"supporting_source_requirements":[{"requirement_id":"JDDG25-14.8.3.3-R05","section":"14.8.3.3","title":"DESIGN ANALYSIS","fact":"Seismic-protection calculations may be performed by a registered U.S. engineer or a Japanese 1st Class Qualified Architect."},{"requirement_id":"JDDG25-14.8.4.3-R02","section":"14.8.4.3","title":"DESIGN ANALYSIS","fact":"All final calculations are to be included in the Final Design Analysis."}],"references_resolved":[]}